WineZone Air Handler 5800 Series
5800 BTUH Air Handler Specifications
For wine cellar less than 2,000 cubic feet
Condenser:
Voltage |
HP |
Ampacity Max. |
Fuse Min. |
Wire Size |
RLA/LRA |
230/208-60-1 |
1 |
8 |
15 |
14-2 w/Gr |
5.5/31.0 |
Water Cooled condensers available
3/8" x 1/2" line set. 80 equivalent feet maximum
Unit is not precharged and must be evacuated
Compatible for use with refrigerants R-22, NU-22B, MO99 and R-427A
Dimensions:
Indoor Unit: 27" x 24.5" x 18"
Outdoor Unit: 27" x 24.5" x 22"
Vertical Air Handler:
Voltage |
HP |
Ampacity Max. |
Fuse Min. |
Wire Size |
Filter |
115-60-1 3spd. |
1/6 |
3.7 |
15 |
14-2 w/Gr |
11.5 x 19.25 |
Receives load voltage from condenser
Line voltage run to condenser
585 CFM @ 0.08" static pressure. 8 x 16 supply trunk, 8 x 20 return trunk recommended, 2" duct wrap min.
3/4" FPT drain, trap required
Dimensions:
Vertical Unit: 24" W x 13" D x 29" H
Optional Horizontal Unit: 25" W x 32.5" D x 14.5" H
Thermostat:
Johnson Controls A350 series temperature controls
W351 series humidity controls
Y350 Power Module requires 115 or 220 volt supply
18 gauge 10 conductor to condenser. 5 conductor to HE-67XX sensor
Humidifier:
Requires 115 volt receptacle
24 volt control from condenser
Y350 and humidifier may use same circuit. Check local codes.
Dehumidification:
Duct heater requires 115 volt 15 Amp circuit
Y350, humidifier, and duct heater may use same circuit. Check local codes.
Approximate Shipping Weight:
370-390 lbs.